TOP > Chemiluminescence Analyzer Series System

Chemiluminescence Analyzer Series

There are three kinds of product models and four kinds of sample chambers.
You can select and combine to make the best system for your research.

Product model

CLA-FS3

Ultra high sensitive
CL Intensity & Spectrum Measurement type.

Counting Single photon counting with photomulitiplier tube (PMT)
Detection Wavelength 300nm-850nm
(Center wavelength:420nm)
Cut Filter 330nm-700nm (20 filters with an interval of 20nm)
Filter Exchange Device Rotating table with 20 filters controlled by computer.
Temprature Control Electronic Heater embedded in sample chamber temperrature controller is on the front panel (Temp.control can be done manually or computer)
Sample Chamber used CLS-FL / 50C or less
CLS-MX3 / 100C or less
CLS-ST3 / 160C or less
CLS-LA3 / 100C or less
Output Signal Recorder Output : 1.0 V/F.S
Integrator Output : 1.0V/F.S
Interface RS-232 Interface (com1,com2)
Power Source
Size & weight
AC 100V, 50/60Hz, 5A
520(W)×420(D)×547(H) mm, Approx. 50kg

CLA-ID3

Ultra high sensitive
CL Intensity Measurement type.

Counting Single photon counting with photomulitiplier tube (PMT)
Detection Wavelength 300nm-650nm
(max.quantum efficiency: 430nm)
Cut Filter None
Filter Exchange Device None
Temprature Control Electronic Heater embedded in sample chamber temperrature controller is on the front panel (Temp.control can be done manually or computer)
Sample Chamber used CLS-FL / 50C or less
CLS-MX3 / 100C or less
CLS-LA3 / 100C or less
Output Signal Recorder Output : 1.0 V/F.S
Integrator Output : 1.0V/F.S
Interface RS-232 Interface (com1)
Power Source
Size & weight
AC 100V, 50/60Hz, 5A
310(W)×420(D)×524(H) mm, Approx. 35kg

CLA-FL2

Ultra high sensitive
Flow measurement type
l.e. for the HPLC detector.

Counting Single photon counting with photomulitiplier tube (PMT)
Detection Wavelength 300nm-650nm
(max.quantum efficiency: 430nm)
Cut Filter None
Filter Exchange Device None
Temprature Control Electronic Heater embedded in sample chamber temperrature controller is on the front panel
Sample Chamber used CLS-FL / 50C or less
Output Signal Recorder Output : 1.0 V/F.S
Integrator Output : 1.0V/F.S
Interface None
Power Source
Size & weight
AC 100V, 50/60Hz, 5A
310(W)×420(D)×524(H) mm, Approx. 35kg

Sample Chamber

CLS-ST3

Heating type

Sample Dish A stainless steel sample dish is put in this holder
Injection Port 1 port on the front panel
( a TEIC needle is necessary)
Electrical Heater Fixed under the holder maximum temperature is 160℃
Functions IN (inlet) & OUT (outlet) on the front panel
Size
Weights
221(W) x 357(D) x 121(H) mm
approx 4kg

CLS-MX3

Mixing type

Sample Dish A stainless steel sample dish is put in this holder
Injection Port 1 port on the front panel
( a TEIC needle is necessary)
Max. Temp. 100℃
Gas Port IN (inlet) & OUT (outlet) on the front panel
Mixing Function Magnetic stirrer is built-in under sample dish holder
Size
Weights
221(W) x 357(D) x 121(H) mm
approx 4kg

CLS-LA3

Laser Irradiation type

Sample Dish A stainless steel sample dish is put in this holder
Max. Temp. 100℃
Gas Port IN (inlet) & OUT (outlet) on the front panel
Laser Unit Laser Diode
375nm (Max 15mW) or 405nm (Max 30mW)
Size
Weights
221(W) x 357(D) x 121(H) mm
approx 4kg

CLS-FL

Flow type. For the detector of HPLC

Sample Dish Spiral Flow Tubing,
Material: Teflon
Injection Port 2 ports on the front panel
Electrical Heater Fixed under the holder maximum temperature is 50℃
Functions A mixing device is fixed in the Sample Chamber. 1 outlet for drain is fixed on the front panel. Leak sensor is built-in.
Size
Weights
221(W) x 357(D) x 121(H) mm
approx 2kg
Copyright (c) TOHOKU ELECTRONIC INDUSTRIAL Co.,Ltd. All Rights Reserved.